Determination of soil moisture content is of vital importance to many fields of study; civil engineering, hydrology, agriculture, geology, ecology and forestry. The occurrence of impact crater in Bukit Bunuh, a meteorite impacted area, made it an area of great interest to many researchers. In view of the process of impact cratering, the subsurface soil characteristics such as moisture content o...
متن کاملRevised for: Correspondence to: Plant and Soil
While agricultural research has traditionally focused on average environmental conditions, environmental variability, independent of the mean, can also have biological consequences. Using lettuce (Lactuca sativa) as a model system, we tested two hypotheses: (1) increased temporal variability in water supply impacts plant growth, yield, photosynthesis, water relations, and nutrition and (2) AM f...
متن کاملA descent method for explicit computations on curves
It is shown that the knowledge of a surjective morphism $Xto Y$ of complex curves can be effectively used to make explicit calculations. The method is demonstrated by the calculation of $j(ntau)$ (for some small $n$) in terms of $j(tau)$ for the elliptic curve with period lattice $(1,tau)$, the period matrix for the Jacobian of a family of genus-$2$ curves complementing the classi...
متن کاملSoil Resistivity Data Computations; Single and Two - Layer Soil Resistivity Structure and Its Implication on Earthing Design
Performing High Voltage (HV) tasks with a multi craft work force create a special set of safety circumstances. This paper aims to present vital information relating to when it is acceptable to use a single or a two-layer soil structure. Also it discusses the implication of the high voltage infrastructure on the earth grid and the safety of this implication under a single or a two-layer soil str...
متن کاملDIVISION S-1—SOIL PHYSICS Electrical Resistivity Imaging for Detecting Soil Cracking at the Centimetric Scale
soil water content. Mackie-Dawson et al. (1989) studied the evolution of the cracking system in the first 10 cm Electrical resistivity measurements at high resolution (1.5-cm elecof soil by using vertical image analysis. They observed trode spacing) were performed to detect, from the soil surface, small cracks developing within the soil. We recorded a vertical electrical significant soil struct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan
سال: 1952
ISSN: 0387-1177,2433-0019