4Pi-confocal imaging in fixed biological specimens.
By combining the wavefronts produced by two high-aperture lenses, two-photon 4Pi-confocal microscopy allows three-dimensional imaging of transparent biological specimens with axial resolution in the 100-140-nm range. We reveal the imaging properties of a two-photon 4Pi-confocal microscope as applied to a fixed cell. We demonstrate that a fast, linear point deconvolution suffices to achieve axia...
متن کامل4Pi-Confocal Microscopy Is Coming of Age
Fluorescence microscopy is one of the most favored imaging techniques in biological research: It allows non-invasive imaging of sub-cellular structures inside of live cells, specifically labeled by biological markers such as the green fluorescent protein (GFP). The confocal laser-scanning microscope or its multiphoton versions stand out by their ability to provide 3D-images. However, like any o...
متن کامل4Pi confocal microscopy with alternate interference.
We introduce 4Pi confocal microscopy with destructive interference of converging waves. Linear lobe deconvolution as well as nonlinear restoration of 4Pi confocal raw data with their point-spread functions (PSF's) leads to almost-identical images, irrespective of whether the 4Pi confocal PSF relies on constructive or destructive interference. Three-dimensional imaging of microtubules of a mouse...
متن کاملDeep tissue fluorescent imaging in scattering specimens using confocal microscopy.
In scattering specimens, multiphoton excitation and nondescanned detection improve imaging depth by a factor of 2 or more over confocal microscopy; however, imaging depth is still limited by scattering. We applied the concept of clearing to deep tissue imaging of highly scattering specimens. Clearing is a remarkably effective approach to improving image quality at depth using either confocal or...
متن کاملAxial apodization in 4Pi-confocal microscopy by annular binary filters.
We present a novel technique for considerably decreasing the sidelobe height of the axial point-spread function of one-photon 4Pi-confocal microscopes. By means of a numerical example, in which the ratio between the excitation and the fluorescence wavelengths was set to epsilon = lambdaexc/lambdadet = 0.8, we show that simply inserting a pair of properly designed two-ring binary masks in the il...