480. Study on contrast of Variable angle spin echo and Gradient field echo with contrast map
نویسندگان
چکیده
منابع مشابه
comparison of maximum signal intensity of magnevist contrast agent in modified t1 weighted spin echo, t1 weighted fast spin echo and t1 weighted gradient echo sequences
background: nowadays mri examinations have been widely used in clinical applications for many diagnoses. the use of contrast agent in mri improves lesion detection and characterization and causes more accurate diagnosis. objectives: the aim of this study was comparing to optimal dose of magnevist contrast agent in modified t1w se (spin echo), t1w fse (fast spin echo) and t1w gre (gradient ech...
متن کاملPerfusion MRI of the human brain with dynamic susceptibility contrast: gradient-echo versus spin-echo techniques.
In this study, spin-echo and gradient-echo-based perfusion magnetic resonance imaging (MRI) techniques are systematically compared with respect to their application in the human brain. Six healthy subjects were evaluated with both techniques consecutively and injected twice with a gadolinium-based contrast agent. In accordance with theoretical predictions and with previous animal experiments, t...
متن کاملProbing Lung Microstructure with Gradient Echo Plural Contrast Imaging
Introduction The in vivo lung morphometry technique, relying on measuring Brownian motion of inhaled hyperpolarized gas in lung airspaces, makes it possible to obtain in vivo information on lung microstructure at the alveolar level [1-3]. This communication presents a theoretical background and experimental method for a new approach to study lung microstructure, that is based on T2*-relaxation ...
متن کاملComparison of dynamic contrast-enhanced gradient-echo and spin-echo sequences in MR of head and neck neoplasms.
PURPOSE To investigate the utility of dynamic contrast-enhanced gradient-echo MR imaging of head and neck lesions and to compare this technique with the commonly used spin-echo contrast-enhanced fat-saturation technique. METHODS Twenty-two patients with a total of 23 head and neck neoplasms underwent dynamic gradient-echo and spin-echo MR imaging studies. The spin-echo and dynamic gradient-ec...
متن کاملEffect of Low Refocusing Angle in T1-Weighted Spin Echo and Fast Spin Echo MRI on Low-Contrast Detectability: A Comparative Phantom Study at 1.5 and 3 Tesla
MRI tissue contrast is not well preserved at high field. In this work, we used a phantom with known, intrinsic contrast (3.6%) for model tissue pairs to test the effects of low angle refocusing pulses and magnetization transfer from adjacent slices on intrinsic contrast at 1.5 and 3 Tesla. Only T1-weighted spin echo sequences were tested since for such sequences the contrast loss, tissue heatin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1993
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003325064