Localized eddy current compensation using quantitative field mapping.

Eddy current effects induced by switched gradients in proximal conducting structures are traditionally reduced by applying preemphasis currents whose amplitudes and decay characteristics must be set to offset the eddy current fields. We present an expeditious, localized, and quantitative method for mapping and adjusting the parameters for eddy current compensation. Mapping is based on analysis ...

متن کامل

Correction of phase effects produced by eddy currents in solvent suppressed 1H-CSI.

Accurate phasing of MRS spectra is often difficult unless time varying phase effects produced by gradient-induced eddy currents that persist during data acquisition are eliminated. This effect is particularly problematic in 1H-CSI spectra where frequency shifts produced by static field inhomogeneity and phase shifts produced by eddy currents combine. In this paper we present a method that corre...

متن کامل

Quantification and compensation of eddy-current-induced magnetic-field gradients.

Two robust techniques for quantification and compensation of eddy-current-induced magnetic-field gradients and static magnetic-field shifts (ΔB0) in MRI systems are described. Purpose-built 1-D or six-point phantoms are employed. Both procedures involve measuring the effects of a prior magnetic-field-gradient test pulse on the phantom's free induction decay (FID). Phantom-specific analysis of t...

متن کامل

Inherent eddy current compensation for high-resolution DTI using bipolar diffusion gradients

Introduction: Clinical diffusion-weighted imaging (DWI) often employs a single-shot echo-planar imaging (EPI) readout to increase acquisition speed. This comes at a cost, however, since conventional DWI sequences employ a spin echo (SE) sequence with either unipolar or bipolar diffusion-sensitizing gradients on both sides of the 180º refocusing pulse. This configuration shortens the separation ...

متن کامل

Eddy-current testing with the Expected Improvement optimization algorithm

This paper presents an inverse problem methodology in the domain of non-destructive testing, and more precisely eddy-current testing. Our objective is to use a precise but expensive-to-evaluate model of the electromagnetic induction phenomenon in a conductive material and to estimate the characteristics of a flaw by minimization of a regularized criterion with the Expected Improvement (EI) glob...