منابع مشابه
Patellofemoral joint is an under reported joint in MRI knee – A retrospective, cross-sectional study
BACKGROUND Patellofemoral joint (PFJ) pathology accounts for upto 40% of cases of knee pain. It has been suggested that PFJ pathology may be underreported in Magnetic Resonance Imaging (MRI) Knee reports. The objective of this study was to elucidate whether PFJ was reported in MRI knee reports at our institution. MATERIALS AND METHODS A retrospective review of 103 consecutive Knee MRIs over a...
متن کاملPROPHYLACTIC INTRA-JOINT APPLICATION OF VANCOMYCIN IN TOTAL KNEE ARTHROPLASTY
This was Presented in 5th International Congress of Iranian Iranian Society of Knee Surgery, Arthroscopy, and Sports Traumatology (ISKAST), 14-17 Feb 2018- Kish, Iran
متن کاملRapid 3D-Sodium MRI of Knee Joint In-vivo at 7T
Introduction Loss of glycosaminoglycans (GAG) is a signature of early osteoarthritis (OA). Although sodium MRI has been shown to correlate linearly with GAG concentration (1, 2), it poses major challenges at clinical magnetic field strengths (1.5T/3.0T) in terms of low signal-to-noise (SNR), poor spatial resolution and long acquisition times due to low natural abundance, low sodium concentratio...
متن کاملCo-relation of Mri and Arthroscopy in Soft Tissue Injuries of Knee Joint
Introduction: Knee is most frequently injured joints among because of its anatomical structure and its exposure to external forces and the functional demands placed on it. Magnetic resonance imaging (MRI) helped in the diagnosis of intra articular soft tissue injury without arthroscopy. Advantages over MRI are non-invasive, minimal patient discomfort and easy visibility of posterior cruciate li...
متن کاملComparison of T1rho imaging between spoiled gradient echo (SPGR) and balanced steady state free precession (b-FFE) sequence of knee cartilage at 3T MRI.
PURPOSE To investigate the difference in T1rho profiles of the entire femoral cartilage between SPGR and b-FFE sequences at 3.0T. MATERIALS AND METHODS 20 healthy volunteers were enrolled in this study. T1rho images of each subject were acquired with two types of pulse sequences: SPGR and b-FFE. Femoral cartilage segmentation was performed by two independent raters slice-by-slice using Matlab...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1994
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003326221