410: Total Glucose Control (TGC): A Glucose Control Project for Staff Nurses
نویسندگان
چکیده
منابع مشابه
Optimal intelligent control for glucose regulation
This paper introduces a novel control methodology based on fuzzy controller for a glucose-insulin regulatory system of type I diabetes patient. First, in order to incorporate knowledge about patient treatment, a fuzzy logic controller is employed for regulating the gains of the basis Proportional-Integral (PI) as a self-tuning controller. Then, to overcome the key drawback of fuzzy logic contro...
متن کاملAnalytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملoptimal intelligent control for glucose regulation
this paper introduces a novel control methodology based on fuzzy controller for a glucose-insulin regulatory system of type i diabetes patient. first, in order to incorporate knowledge about patient treatment, a fuzzy logic controller is employed for regulating the gains of the basis proportional-integral (pi) as a self-tuning controller. then, to overcome the key drawback of fuzzy logic contro...
متن کاملMoving beyond tight glucose control to safe effective glucose control
The impressive benefits related to the use of tight glucose control by intensive insulin therapy have not been reproduced until now in multicenter large-scale prospective randomized trials. Although the reasons for these failures are not entirely clear, we suggest the use of a stepwise approach - Safe, Effective Glucose Control - that will essentially target an intermediate blood glucose level....
متن کاملanalytical performance and quality control of a glucose monitor system
background and objective: the reliability and validity of monitors for self-monitoring of blood glucose are debated. we evaluated the analytical performance of accu-check active (boehringer mannheim, roche) which is one of the most commonly used monitors in iran. material and methods: we compared the monitor readings with the reference values by percentage of values within certain intervals of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biology of Blood and Marrow Transplantation
سال: 2008
ISSN: 1083-8791