400 Hz Volume Rate Swept-Source Optical Coherence Tomography at 1060 nm Using a KTN Deflector

نویسندگان

چکیده

In this Letter, a swept-source optical coherence tomography (SS-OCT) instrument employing an innovative scanning protocol for high-speed volumetric rate imaging is demonstrated. The source tunable laser based on supercontinuum pumped with femtosecond pulses, followed by time-stretched delay fiber. equipped ultra-fast lateral scanner, KTN crystal, driven at 100 kHz. letter proves the utility of combining scanner swept to provide A-scans repetition 40 MHz and unprecedented 3D-OCT volume acquisition 400 Hz.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-Speed Optical Coherence Tomography System Using a 200-kHz Swept Light Source with a KTN Deflector

We demonstrate a high-speed swept-source optical coherence tomography (SS-OCT) system, which is based on a highspeed swept light source and a Mach-Zehnder interferometer with a high-speed photodetector. The light source is an external-cavity laser tuned by a KTN electro-optic deflector, which exhibits a very fast response and large deflection. The scanning wavelength range is almost 80 nm up to...

متن کامل

In vivo human choroidal vascular pattern visualization using high-speed swept-source optical coherence tomography at 1060 nm.

PURPOSE To investigate the retinal and choroidal vascular pattern, structure, and thickness using high-speed, high axial resolution, swept-source optical coherence tomography (SS-OCT) at 1060 nm, demonstrating enhanced penetration through all choroidal layers. METHODS An ophthalmic SS-OCT system was developed operating at 57,000 A-lines/s with 5.9 μm axial resolution and was used to collect 3...

متن کامل

In vivo human retinal and choroidal vasculature visualization using differential phase contrast swept source optical coherence tomography at 1060 nm

A differential phase contrast (DPC) method is validated for in vivo human retinal and choroidal vasculature visualization using high-speed swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was identified as regions of motion by creating differential phase variance (DPV) tomograms: multiple B-scans were collected of individual slices through the retina and the varian...

متن کامل

Differential phase-contrast, swept-source optical coherence tomography at 1060 nm for in vivo human retinal and choroidal vasculature visualization.

Human retinal and choroidal vasculature was visualized by a differential phase-contrast (DPC) method using high-speed, swept-source optical coherence tomography (SS-OCT) at 1060 nm. The vasculature was recognized as regions of motion by creating differential phase-variance (DPV) tomograms: multiple B-scans of individual slices through the retina were collected and the variance of the phase diff...

متن کامل

Development of Optical Coherence Tomography Using KTN Optical Probe

We have developed optical coherence tomography system with KTN optical probe for a diagnosis in the orthopedic surgery fields. The present system demonstrates that biological image was measured by using KTN optical scanner for having degree of freedom in sample arm as optical coherence tomography. In addition, the developed optical coherence tomography (OCT) system has shown feasibility for ima...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Photonics Technology Letters

سال: 2022

ISSN: ['1941-0174', '1041-1135']

DOI: https://doi.org/10.1109/lpt.2022.3212015