3D‐printable lung phantom for distal falloff verification of proton Bragg peak
نویسندگان
چکیده
منابع مشابه
A new model for Spread Out Bragg Peak in proton therapy of uveal melanoma
In this research, in order to improve our calculations in treatment planning for proton radiotherapy of ocular melanoma, we improved our human eye phantom planning system in GEANT4 toolkit. Different analytical models have investigated the creating of Spread Out Bragg Peak (SOBP) in the tumor area. Bortfeld’s model is one of the most important analytical methods. Using convolution method, a new...
متن کاملTissue inhomogeneity in proton therapy and investigation of its effects on BRAGG peak by using MCNPX code
Background: Hadron therapy for malignant tumor is becoming increasingly popular. There are many factors which effect on implementation of a proper treatment planning. The purpose of this work is to investigate the inhomogeneity effects as affecting factor on proton range, Full width at half maximum (FWHM) and 20% position of penumbra (P20) by MCNPX code. Materials and Methods: An inhomogeneous ...
متن کاملبررسی اثر تغییر انرژی بر توزیع عمق-دوز در پروتون درمانی تومور چشمی با استفاده از کد MCNPX
Introduction: Depth-dose distribution curve of protons in the matter has a maximum is called Bragg peak. Bragg peak of a monoenergetic proton beam is too narrow. The spread out Bragg peak should be created for full coverage of the tumor. The spread out Bragg peak is obtained in the depth of the tumor with superposition of the several Bragg peaks. The aim of this study was coverage of an eye tum...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملCalculation of Neutron Dose Ratio of Heart, Lung and Liver due to breast cancer Proton Therapy using MCNPX code
Introduction: The proton beam produced in particle accelerators has an appropriate therapeutic potential. In this research, proton therapy of breast cancer is simulated using the MCNPX code in a MIRD phantom, also the contribution of scattered neutron dose during the proton therapy were calculated for the Heart, Lung and Liver. Materials and Methods: For si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2019
ISSN: 1526-9914,1526-9914
DOI: 10.1002/acm2.12706