3D HYSTERETIC MODEL FOR PIER BASE-TO-FOOTING CONNECTIONS
نویسندگان
چکیده
منابع مشابه
Hysteretic Behavior of Prestressed Concrete Bridge Pier with Fiber Model
The hysteretic behavior and seismic characteristics of the prestressed concrete bridge pier were researched. The effects of the prestressed tendon ratio, the longitudinal reinforcement ratio, and the stirrup reinforcement ratio on the hysteretic behavior and seismic characteristics of the prestressed concrete bridge pier have been obtained with the fiber model analysis method. The analysis show...
متن کاملSeismic Retrofit of Bridge Steel Truss Pier Anchorage Connections
In assessments of the seismic adequacy of existing steel bridges, the steel-to-concrete anchorage connections typically found at the base of steel truss piers can be potentially vulnerable, having little to no ductility and inadequate strength to resist seismic demands. Many other non-ductile failure locations may also exist along the seismic load path. Failure would result in unacceptable perf...
متن کاملA fault detection method for hysteretic base-isolation systems
This paper proposes a fault detection method for hysteretic base-isolation systems. One of the key contr butions of this work is a Lyapunov-based restoring force observer that leads to the design of a robust fault detection scheme. The different fault types considered are stiffness and damping variations in the system. The proposed fault estimation method provides a direct estimate of the size ...
متن کاملThe Effects of Internal and External Stiffeners on Hysteretic Behavior of Steel Beam to CFT Column Connections
This study focuses on performance of H-shaped steel beams to CFT column rigid connections. To this end, the effects of internal and external stiffeners on hysteretic behavior of connections were studied. Comparative numerical analyses carried out on eight different connections. To this end finite element models were prepared using ANSYS and nonlinear cyclic analyses carried out. Results of this...
متن کاملMathematical Modeling of Column-Base Connections under Monotonic Loading
Some considerable damage to steel structures during the Hyogo-ken Nanbu Earthquake occurred. Among them, many exposed-type column bases failed in several consistent patterns, such as brittle base plate fracture, excessive bolt elongation, unexpected early bolt failure, and inferior construction work, etc. The lessons from these phenomena led to the need for improved understanding of column base...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Doboku Gakkai Ronbunshuu A
سال: 2008
ISSN: 1880-6023
DOI: 10.2208/jsceja.64.513