370 Measurment of X-Rays Spectrum for Cadmium Telluride Detector
نویسندگان
چکیده
منابع مشابه
Evaluation of a small cadmium zinc telluride detector for scintimammography.
UNLABELLED The purpose of this study was to evaluate a small semiconductor-based gamma camera that may have applications in scintimammography. METHODS A small cadmium zinc telluride (CZT) detector was evaluated. The detector had a field of view of 20 x 20 cm with detector elements of 2.5 x 2.5 mm in size. Both short-bore (35 mm) and long-bore (50 mm) collimators, matched to the geometry of th...
متن کاملX-ray Energy Response of Mercury Cadmium Telluride Near-infrared Detector Arrays
A technique involving Fe X-rays provides a straightforward method to measure the response of a detector. The detector’s response can lead directly to a calculation of the conversion gain (e ADU), as well as aid detector design and performance studies. We calibrate the Fe X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 μm flight grade detectors. The results show t...
متن کاملThe Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway
This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...
متن کاملdevelopment of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles
a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...
Measurement of stereotactic beam data of 9 MV X-rays using diode detector
Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1995
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00001353141