367. Quantitative CT using Post-patiant Phantom Scan method
نویسندگان
چکیده
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملDesign and Fabrication Process of CT number Linearity and Homogeneity Phantom CT Scan
Introduction: One of the most valuable goals of phantoms, replacing with human goals in the field of research and quality control of diagnostic X-ray systems. There are various algorithms and methods for obtaining Homogeneity and CT number linearity for CT scan device. One of the most famous of these methods, the method is to use a uniform and homogeneous environment to comput...
متن کاملA novel dual energy CT-based attenuation correction method in PET/CT systems: A phantom study
In present PET/CT scanners, PET attenuation correction is performed by relying on the information given by CT scan. In the CT-based attenuation correction methods, dual-energy technique (DECT) is the most accurate approach, which has been limited due to the increasing patient dose. In this feasibility study, we have introduced a new method that can implement dual-en...
متن کاملAge Differences of Human Frontal Sinus Measurements using CT Scan
Background and Objectives: The frontal sinus is regarded as one of the human paranasal sinuses located in the frontal bone as a triangular-shaped cavity, which originates as separated space from the anterior ethmoid cells. Computed Tomography (CT) is a completely non-destructive technique that uses a high density of contrast to identify the air inside any bony sinus with soft tissue demarcated ...
متن کاملCT scan prediction of late post-traumatic epilepsy.
Out of 233 patients admitted for head trauma during 1977-1978, 93 had a CT scan examination within the first 48 hours. Forty-nine of these had at least one clinical risk factor for post-traumatic epilepsy. Ten of this group developed post-traumatic epilepsy. In all cases early CT scan showed focal brain damage, which was related more significantly to post-traumatic epilepsy than to risk factors.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Japanese Journal of Radiological Technology
سال: 1992
ISSN: 0369-4305,1881-4883
DOI: 10.6009/jjrt.kj00003500763