3-D Ultrasound Elastography Reconstruction Using Acoustically Transparent Pressure Sensor on Robotic Arm

نویسندگان

چکیده

Biopsy of breast lesions only visible on MRI may benefit from patient-specific finite-element modeling the breast. This requires acquisition heterogeneous elasticity distribution. An acoustically transparent pad has been developed which enables strain elastography imaging using ultrasound without need for additional force or pressure sensors. The is known a priori while change in thickness detectable by edge detection. Based calculated distribution across pad, inner tissue can be approximated. measured cross-correlation block matching algorithm and these measurements estimated. probe with moved over surface robot arm. At sixteen sites one phantom performed an inward push movement perpendicular to surface. scans were post-processed reconstruct map local plane. While it challenging accurately estimate stress deeper tissue, certain features such as skin effectively distinguished underlying soft demonstrates potential system.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An LPV Approach to Sensor Fault Diagnosis of Robotic Arm

One of the major challenges in robotic arms is to diagnosis sensor fault. To address this challenge, this paper presents an LPV approach. Initially, the dynamics of a two-link manipulator is modelled with a polytopic linear parameter varying structure and then by using a descriptor system approach and a robust design of a suitable unknown input observer by means of pole placement method along w...

متن کامل

Freehand ultrasound elastography with a 3-D probe.

This paper presents the first near-real-time freehand ultrasound elastography system using a (3-D) mechanical probe. Acquisition is complete within two sec, and only an additional 20 sec are required for generation of a full 3-D strain volume. The strain is axial, with estimates of lateral and elevational tissue movement used to increase the accuracy of the axial strain measurement. This is the...

متن کامل

BreastCare Breast Sonography – 2 D , 3 D , 4 D Ultrasound or Elastography ?

Zusammenfassung Diese Publikation versucht die Frage zu beantworten, ob Elastographie den 2D-, 3Dund 4D-Ultraschall der Brust ersetzen kann oder ob die Elastographie als Zusatz technik zur B-Mode-Bildgebung zum Einsatz kommt. Abgesehen von der Durchblutungsstudie eines Herdes basiert die Breast Imaging and Reporting Data System (BI-RADS)-Kriterienanalyse auf dem B-Mode. Sonoelastographie stellt...

متن کامل

ultrasound elastography using emd analysis

ultrasoundelastographyisanon-invasivemethodwhichimagestheelasticityofsoft-tissues. tomakeanimage, preandafterasmallcompression, ultrasoundradio frequency(rf)signalsareacquiredandthetimedelaysbetweenthemareestimated. thefirstdifferentiationofdisplacementestimationsiscalledelastogram. inthisstudy, wearegoingtomakeanelastogramusingtheprocessingmethodnamed empirical mode decomposition (emd). emdisa...

متن کامل

3D Elastography Using Freehand Ultrasound

We present an elastography system using freehand 3D ultrasound. A review is provided of the standard elastography methods that have been adapted for this purpose. The scanning protocol is simple and promising results are presented of 3D strain images from freehand scans. Robustness is a problem, however, and the main sources of error are explained. Measures have been developed to improve the qu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE transactions on medical robotics and bionics

سال: 2021

ISSN: ['2576-3202']

DOI: https://doi.org/10.1109/tmrb.2020.3042982