Helical MR: continuously moving table axial imaging with radial acquisitions.
A technique for extended field of view MRI is presented. Similar to helical computed tomography, the method utilizes a continuously moving patient table, a 2D axial slice that remains fixed relative to the MRI magnet, and a radial k-space trajectory. A fully refocused SSFP acquisition enables spatial resolution comparable to current clinical protocols in scan times that are sufficiently short t...
متن کاملView Sharing in slice direction for continuously moving table acquisitions: Application to TOF venography
Introduction To increase the temporal resolution in time-resolved MRI, several view sharing (VS) techniques have been developed. Typically, high spatial frequencies are not fully sampled for all time frames and data from the different time frames are combined to generate full k-space data [1, 2]. In this study the VS concept was applied to share data between different slice positions for axial ...
متن کاملTime efficient parallel imaging for 2D multi-slice MRI with continuously moving table
Introduction In whole body MRI with continuously moving table (CMT-MRI) the acquisition time is an important issue. In particular for examinations performed during breath holding, the number of required breath holding phases should be small and the duration of each breath holding phase as short as possible. In the 2D multi-slice approach to CMT-MRI investigated here, parallel imaging with no hi...
متن کاملStaging of Ovarian Cancer with Continuously Moving Table Mr Acquisitions: a Comparison to Computed Tomography
INTRODUCTION One in 70 women in the Western World will develop ovarian cancer (lifetime risk 1.4%). In Europe, it is estimated that 61,000 cases are diagnosed, and 39,000 deaths from ovarian cancer occur annually. More than 70% of patients with ovarian cancer are diagnosed in an advanced tumor stage. The tumor stage at the time of diagnosis is generally considered as the most important prognost...
متن کاملDo we need suspended breathing with real-time axial continuously moving table MR imaging?</I>
A. Zielonka, S. Kinner, M. O. Zenge, M. E. Ladd, S. C. Ladd Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany Introduction In recent years interest has increased in whole-body magnetic resonance (MR) imaging with continuous table movement. Advantages are that there are no artifacts at the borders of the scan volumes and their tra...