292. Usefulness of scatter corection by Triple Energy Window method. : In ^<123>I-BMIPP and ^<123>I-MIBG SPECT imaging.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

123I-ioflupane brain SPECT and 123I-MIBG cardiac planar scintigraphy combined use in uncertain parkinsonian disorders

We evaluated the clinical usefulness of the combined use of I-ioflupane brain single photon emission computed tomography (SPECT) and I-metaiodobenzylguanidine (MIBG) cardiac scintigraphy in discriminating uncertain parkinsonism with vascular lesions in striatal nuclei at magnetic resonance imaging (MRI). Forty-three consecutive patients with uncertain parkinsonism and vascular lesions at MRI in...

متن کامل

Scatter correction based on an artificial neural network for 99mTc and 123I dual-isotope SPECT in myocardial and brain imaging.

UNLABELLED The aim of this study was to elucidate the clinical usefulness of scatter correction with an artificial neural network (ANN) in 99mTc and 123I dual-isotope SPECT. METHODS Two algorithms for ANN scatter correction were tested: ANN-10 and ANN-3 employing 10 and 3 energy windows for data acquisition, respectively. Three patients underwent myocardial or brain SPECT with one of the foll...

متن کامل

123I-MIBG SPECT for Evaluation of Patients with Heart Failure.

Heart failure (HF) is characterized by activation of the sympathetic cardiac nerves. The condition of cardiac sympathetic nerves can be evaluated by (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging. Most cardiac (123)I-MIBG studies have relied on measurements from anterior planar images of the chest. However, it has become progressively more common to include SPECT imaging in clinical and r...

متن کامل

Impaired lung 123I-MIBG uptake on SPECT in pulmonary emphysema.

UNLABELLED The aim of this study was to evaluate impaired lung uptake of (123)I-metaiodobenzylguanidine ((123)I-MIBG) on SPECT, compared with perfusion SPECT and morphologic CT, in patients with pulmonary emphysema (PE). METHODS (123)I-MIBG SPECT was performed at 15 min and 4 h after intravenous injection of (123)I-MIBG in 36 PE patients with a history of smoking and variable-extent low-atten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1994

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00003326092