273) Experimental Study on Steel Space Truss named Steel Shell-GABION(Structure)

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Investigation on Seismic Behavior of Steel Truss-RC Column Hybrid Structure with Steel Diagonal Braces

This paper aims to provide an experimental support on seismic performance evaluation of the steel braced truss-RC (reinforced concrete) column hybrid structure, which could be applied as the air-cooled supporting structural system in large-capacity thermal power plants located in strong earthquake prone regions. A series of pseudo-dynamic tests (PDTs) and quasi-static tests (QSTs) were performe...

متن کامل

An Experimental Study on Seismic Performance of Steel Truss Coupling Beams with Buckling-restrained Brace

Through the pseudo-static test on the steel truss coupling beams with buckling-restrained brace, the bearing capacity, deformation capacity, hysteresis curve, skeleton curve, ductility, Energy Dissipation and stiffness degradation of such coupling beam are understood. The test results show that the steel truss coupling beams with buckling-restrained brace is characterized by bigger bearing capa...

متن کامل

Experimental and Numerical Investigation on Bending Capacity of Steel- concrete Composite Truss Girder

This article presents an experimental investigation on the bending capacity of steel-concrete composite truss girder (SCCTG). Four full-scale specimens named CB1, CB2a, CB2b and CB3 respectively, are tested and numerical analyzed. Stress distribution, load-displacement relationship, load-slip relationship and ultimate bending capacity of SCCTGs are investigated. The results show that SCCTG foll...

متن کامل

Seismic Retrofit of Bridge Steel Truss Pier Anchorage Connections

In assessments of the seismic adequacy of existing steel bridges, the steel-to-concrete anchorage connections typically found at the base of steel truss piers can be potentially vulnerable, having little to no ductility and inadequate strength to resist seismic demands. Many other non-ductile failure locations may also exist along the seismic load path. Failure would result in unacceptable perf...

متن کامل

Experimental seismic testing of a controlled rocking bridge steel truss pier

The experimental seismic testing of a 1/5-length scale model, slender bridge steel truss pier was conducted to investigate the use of a controlled rocking approach as a means of seismic protection. The controlled rocking approach allows the pier to uplift from its base, partially isolating the structure, while passive energy dissipation devices (steel yielding devices, fluid viscous dampers) ar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Transactions of the Architectural Institute of Japan

سال: 1957

ISSN: 0387-1185,2433-0027

DOI: 10.3130/aijsaxx.57.1.0_529