240 nm UV LEDs for LISA test mass charge control
نویسندگان
چکیده
منابع مشابه
New Legionella Control Options by UV and Violet LEDs for Hospitals and Care Facilities
Legionella infections caused by contaminated water are a widespread problem worldwide. Discharge lamps like mercury vapor lamps are widely known for the disinfection properties of their radiation, but they suffer technical disadvantages, like high voltages and toxic content, and are, therefore, not suitable for some infection control applications. New high-intensity ultraviolet (UV) an...
متن کاملUV absorbance of the human cornea in the 240- to 400-nm range.
PURPOSE To determine the UV absorbance of the corneal layers (epithelium, Bowman layer, stroma) in the 240- to 400-nm range. METHODS Consecutive slices (100 microm) of human cadaveric corneas were cut, and the UV absorbance of each sample was determined in a scanning spectrophotometer. In some cases the epithelium was scraped off and its absorbance measured separately. RESULTS The investiga...
متن کاملMaskless photolithography using UV LEDs.
A UV light emitting diode (LED) with a maximum output of 372 nm was collimated using a pinhole and a small plastic tube and focused using a microscope objective onto a substrate for direct lithographic patterning of the photoresist. Movement of the substrate with a motorised linear stage (syringe pump) allowed lines in SU-8 to be pattered with a width down to 35 microm at a linear velocity of 8...
متن کاملDetailed Calculation of Test - Mass Charging in the LISA Mission
The electrostatic charging of the LISA test masses due to exposure of the spacecraft to energetic particles in the space environment has implications in the design and operation of the gravitational inertial sensors and can affect the quality of the science data. Robust predictions of charging rates and associated stochastic fluctuations are therefore required for the exposure scenarios expecte...
متن کاملThe Importance of the 240 nm Absorbance Measurement
The assessment of nucleic acid purity by the A260/A280 ratio has been used for a number of years. This measurement, however, does not provide all the information that investigator needs to assess nucleic acid preparations. The detection of impurities common to nucleic acid preparations that are not detected with absorbance measurements at 260 nm and 280 nm can in most instances be accomplished ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2015
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/610/1/012034