2274 Load Test of Beam-to-Box Column Connections : No. 2(Structures)
نویسندگان
چکیده
منابع مشابه
The Behavior of Type of RC Column-to-Steel Beam Connections and Scrutiny Of Behavior Coefficients
(RCS) frames which are systems that dwell of concrete columns and steel beams , by optimizing the act of compressive strength of concrete and bending strength of steel due to not only a decrease in building weight in comparison to concrete structures but also having a better action in long spans frames . In this paper for analysis RCS behavior, a category of nonlinear Push Over analyses were ...
متن کاملNumerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames
This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...
متن کاملThe Behavior of Type of RC Column-to-Steel Beam Connections and Scrutiny Of Behavior Coefficients
(RCS) frames which are systems that dwell of concrete columns and steel beams , by optimizing the act of compressive strength of concrete and bending strength of steel due to not only a decrease in building weight in comparison to concrete structures but also having a better action in long spans frames . In this paper for analysis RCS behavior, a category of nonlinear Push Over analyses were ...
متن کاملAnalytical and Experimental Investigation of I Beam-to-CFT Column Connections under Monotonic Loading (RESEARCH NOTE)
In this study, the behavior characteristics of I beam-to-concrete filled tube (CFT) column connection is studied through experiment and finite element models under the monotonic loading. To validate the finite element modeling, at first, an experimental model is made and experimented. After validation of the finite element modeling, different models were created in the software. The studied par...
متن کاملComparing Repaired and Undamaged Specimens Test Results of Post-Tensioned Beam to Column Connections
Since, it is essential to provide homeless people by the earthquake with safe, habitable accommodation repairing medium and slight levels of damage at the connection parts should be undertaken. In order to prove that a repaired connection was sufficiently strong, a precast beam to column post tensioned connection was tested in three phases. In phase one, the middle level damage was observed at ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan Summaries of Technical Papers
سال: 1967
ISSN: 2433-0035
DOI: 10.3130/aijsaxxe.42.0_418