Experimental Study on Mechanical Behavior of Shear Connectors of Square Concrete Filled Steel Tube
In order to quantitatively evaluate the shear-bearing capacity of shear connectors of square concrete filled steel tube (CFST), push-out tests on 14 square CFSTs with shear connectors have been carried out. Among the 14 CFSTs, there are 13 specimens with steel plate connectors and one specimen with steel bar connectors. The following factors are investigated to figure out their influences on th...
متن کاملShear Force and Horizontal Relative Displacement Relationship of L-shape Shear Connector Subjected to Strut Compressive Force in Steel-concrete Composite Structure
This study examines the relationship between shear force and horizontal relative displacement of Lshape shear connector by means of beam type test method. An equation for maximum shear force of the specimen which takes into account the effects of size of the shear connector and the concrete strength was proposed. It was found that shear force-horizontal relative displacement relationship can be...
متن کاملEffect of type and distribution of shear studs on the behavior of composite steel-concrete shear walls
In this research in-plane shear Behavior of composite steel-concrete shear walls was investigated considering the Effects of steel plates thickness, spaces between shear studs, shape and type of shear studs and existing of minimum reinforcement in wall section. Several finite element models were analyzed and Numerical results of two models were taken under verification with existent experimenta...
متن کاملSeismic Performance of Steel Plate-Reinforced Concrete Composite Shear Wall
In tall buildings the reinforced concrete (RC) shear wall is one of the predominant structural components used to resist lateral loads induced by earthquakes around the world. Previous research demonstrated that shear walls displayed a sudden loss in lateral capacity due to the wall corner and web crushing in the plastic zone. In addition, it was found that large shear distortions in shear wall...
متن کاملPunching shear strength of steel fibre reinforced concrete slabs
The ultimate strength of reinforced concrete slabs is frequently governed by the punching shear capacity, which may be increased with addition of traditional fitments such as reinforcing steel, headed studs or shear heads. In addition to these traditional methods of strengthening against punching, steel fibre reinforcement has proved to be an effective and viable alternative. The addition of fi...