184 LASER DOPPLER MONITORING OF TISSUE PERFUSION

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a Laser Doppler System for Myocardial Perfusion Monitoring

Coronary artery bypass graft (CABG) surgery is a common treatment for patients with coronary artery disease. A potential complication of CABG is myocardial ischemia or infarction. In this thesis, a method — based on laser Doppler flowmetry (LDF) — for detection of intraand postoperative ischemia by myocardial perfusion monitoring is evaluated. LDF is sensitive to motion artifacts. In previous s...

متن کامل

Tissue blood flow measurement by laser Doppler technique

  Measurement of blood flow and the effects of different factors on tissue blood flow are important fields of research in physiology and pharmacology. So far, different methods have been innovated, using laser light is the Last one. In this article history, principles and specifications of laser technique along with its advantages and disadvantages ( in comparison with other methods) are revie...

متن کامل

Speckles in laser Doppler perfusion imaging.

We report on the quantitative influence of speckles in laser Doppler perfusion imaging. The influence of speckles on the signal amplitude and on the Doppler spectrum is demonstrated experimentally for particle suspensions with different scattering levels and various beam widths. It is shown that the type of tissue affects the instrumental response through the effect of lateral light diffusion o...

متن کامل

Path-length-resolved optical Doppler perfusion monitoring.

We report the first path-length-resolved perfusion measurements on human skin measured with a phase-modulated low-coherence Mach-Zehnder interferometer with spatially separated fibers for illumination and detection. Optical path lengths of Doppler shifted and unshifted light and path-length-dependent Doppler broadening of multiply scattered light from skin are measured from the Doppler broadene...

متن کامل

Perfusion of the femoral head during surgical dislocation of the hip. Monitoring by laser Doppler flowmetry.

We used laser Doppler flowmetry (LDF) with a high energy (20 mW) laser to measure perfusion of the femoral head intraoperatively in 32 hips. The surgical procedure was joint debridement requiring dislocation or subluxation of the hip. The laser probe was placed within the anterosuperior quadrant of the femoral head. Blood flow was monitored in specific positions of the hip before and after disl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pediatric Research

سال: 1985

ISSN: 0031-3998,1530-0447

DOI: 10.1203/00006450-198504000-00214