18) Experimental Study of Eccentrically Loaded Reinforced Concrete Columns. (Report 6)
نویسندگان
چکیده
منابع مشابه
Experimental and numerical study on the structural behavior of eccentrically loaded GFRP columns
Glass fiber reinforced polymer (GFRP) pultruded profiles are being increasingly used in civil engineering applications. Although they offer several advantages over traditional materials, such as high strength, lightness and non-corrodibility, GFRP profiles present low elasticity and shear moduli, which together with their slender walls makes them very prone to buckling phenomena. Several previo...
متن کاملRehabilitation of Reinforced Concrete Columns
In recent years, rehabilitation has been the subject of extensive research due to increased spending on building work and repair of built works. In all cases, it is absolutely essential to carry out methods of strengthening or repair of structural elements, and that following an inspection analysis and methodology of a correct diagnosis. The reinforced concrete columns are important elements in...
متن کاملAmbient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملSeismic Response of Reinforced Concrete Columns
There are a large number of reinforced concrete buildings in seismically active areas of the world that are not built in accordance with modern seismic design provisions such as those published by American Concrete Institution ([ACI] Committee 318, 2008). In the United States and other parts of the developed world, these buildings were constructed between 1930s to mid 1970s according to the bui...
متن کاملEccentrically loaded strip foundation on geogrid-reinforced sand
Results are presented for laboratory model tests conducted to determine the ultimate bearing capacity of an eccentrically loaded strip foundation supported by geogridreinforced sand. Only one type of sand at one relative density of compaction and one type of geogrid were used for the tests. The depth of the foundation was varied from zero to B (width of foundation). Based on the laboratory test...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Institute of Japanese Architects
سال: 1941
ISSN: 0387-1169,2432-9991
DOI: 10.3130/aijsaxxxx.22.0_134