1709 Estimation of Neonatal Endotracheal Tube Resistance by Water Manometer

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

U-Tube Manometer Calibration using ANFIS

This paper deals with the implementation of the Adaptive neuro fuzzy inference system (ANFIS) on a Xilinx based Field Programmable Gate Array Spartan-3E. The implemented hardware is then used to efficiently calibrate the U-Tube manometer, in which the relation between the level of mercury and the Capacitance developed across the Copper Plates of the manometer is highly non-linear. This system s...

متن کامل

Endotracheal tube extubation force: adhesive tape versus endotracheal tube holder.

BACKGROUND Adhesive tape is commonly used to secure the endotracheal tube (ETT) in anesthesia and intensive-care settings. OBJECTIVE To determine the force required to extubate when the ETT is secured with adhesive tape or commercially available ETT holders. METHODS We orally intubated a simulation manikin with a standard 8.0-mm inner-diameter ETT, inflated the cuff to 20 cm H(2)O, and mea...

متن کامل

Endotracheal tube-associated pneumonia.

1. Pneumatikos IA, Dragoumanis CK, Bouros DE: Ventilator-associated pneumonia or endotracheal tube-associated pneumonia? An approach to the pathogenesis and preventive strategies emphasizing the importance of endotracheal tube. ANESTHESIOLOGY 2009; 110:673–80 2. Berra L, Curto F, Li Bassi G, Laquerriere P, Baccarelli A, Kolobow T: Antibacterial-coated tracheal tubes cleaned with the Mucus Shave...

متن کامل

Study on a Concentric Tube Bulb Manometer and its Performance Compared to U-shaped Manometer

This paper presents comparative study of a new type of manometer calledconcentric tube bulb (C.T.B) manometer. Its performance of measuring differential heightis studied against conventional U-shaped manometer. Pressure drops and mass flow ratesare calculated by taking various systems comprising of different flow measuring devicessuch as orifice and venturimeters using both U- shaped and C.T.B ...

متن کامل

Microbial colonization of endotracheal tube in intensive care unit patients

Microbial biofilms has remained a major complication of tracheal intubation in patients requiring ventilator equipment. The aim of this study was to characterize bacterial and fungal biofilms in endotracheal tubes from intensive care unit (ICU) patients in Ahwaz, Iran. In this cross-sectional descriptive study, patients admitted to ICU that required mechanical ventilation for at least 24 hours ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Archives of Disease in Childhood

سال: 2012

ISSN: 0003-9888,1468-2044

DOI: 10.1136/archdischild-2012-302724.1709