162. Energy Subtraction Imaging using Factor Analysis

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

K-edge subtraction imaging using a pixellated energy-resolving detector

This paper presents preliminary work aimed at assessing the feasibility of K-edge subtraction imaging using the spectroscopic information provided by a pixellated energy-resolving Cadmium Zinc Telluride detector, having an active area of 20x20 pixels 250 m in size. Images of a test object containing different amounts of Iodine-based contrast agent were formed above and below the K-edge of Iodin...

متن کامل

A Multi Linear Discriminant Analysis Method Using a Subtraction Criteria

Linear dimension reduction has been used in different application such as image processing and pattern recognition. All these data folds the original data to vectors and project them to an small dimensions. But in some applications such we may face with data that are not vectors such as image data. Folding the multidimensional data to vectors causes curse of dimensionality and mixed the differe...

متن کامل

Imaging Microlens Blends Using Image Subtraction

Blended light is an important source of degeneracy in the characterization of mi-crolensing events, particularly in binary-lens and high magnification events. We show how the techniques of image subtraction can be applied to form an image of the blend with the source removed. In many cases, it should be possible to construct images with very high signal-to-noise ratio. Analysis of these images ...

متن کامل

Imaging of vibrating objects using speckle subtraction.

A simple method for imaging vibrational motion is proposed. The process consists of capturing two speckled images of a region illuminated by coherent radiation. One of the images is captured before the onset of motion and the other during motion. If the mean speckle intensity is below the threshold for detection or above the saturation intensity of the detector, subtracting the two images produ...

متن کامل

Single-exposure dual-energy-subtraction X-ray imaging using a synchrotron source.

Projection radiography of the chest has long been plagued by the presence of bony anatomy obscuring visibility of the lungs and heart. Dual-energy subtraction is a well known method for differentiating bone and soft tissue, but existing techniques are not ideally suited to dynamic imaging. Herein a new technique to address this problem is presented. The harmonic content of a monochromated X-ray...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Radiological Technology

سال: 1990

ISSN: 0369-4305,1881-4883

DOI: 10.6009/jjrt.kj00003322287