125. Electron beam control using multi-leaf collimator
نویسندگان
چکیده
منابع مشابه
Neutron beam characteristics from 50 MeV protons on beryllium using a continuously variable multi-leaf collimator.
The dose distributional properties of a p(50) Be neutron beam using a continuously variable multi-leaf collimator are presented and compared with a 6 MV photon beam. The differences in physical dose delivery between these two radiation modalities are generally insignificant for radiation therapy, and stringent comparisons of neutron and photon treatments should therefore be possible. The flexib...
متن کاملIncorporating multi-leaf collimator leaf sequencing into iterative IMRT optimization.
Intensity modulated radiation therapy (IMRT) treatment planning typically considers beam optimization and beam delivery as separate tasks. Following optimization, a multi-leaf collimator (MLC) or other beam delivery device is used to generate fluence patterns for patient treatment delivery. Due to limitations and characteristics of the MLC, the deliverable intensity distributions often differ f...
متن کاملCharacterization of an extendable multi-leaf collimator for clinical electron beams.
An extendable x-ray multi-leaf collimator (eMLC) is investigated for collimation of electron beams on a linear accelerator. The conventional method of collimation using an electron applicator is impractical for conformal, modulated and mixed beam therapy techniques. An eMLC would allow faster, more complex treatments with potential for reduction in dose to organs-at-risk and critical structures...
متن کاملParallel electron-beam-induced deposition using a multi-beam scanning electron microscope
Lithography techniques based on electron-beam-induced processes are inherently slow compared to light lithography techniques. The authors demonstrate here that the throughput can be enhanced by a factor of 196 by using a scanning electron microscope equipped with a multibeam electron source. Using electron-beam induced deposition with MeCpPtMe3 as a precursor gas, 14 14 arrays of Pt-containing ...
متن کاملSPECT using a specially designed cone beam collimator.
A specially designed high resolution converging collimator having a focal length of 50 cm has been evaluated for cone beam single photon emission computed tomography (SPECT). The focal region was investigated by imaging a point source placed at the expected focal point and along the central ray of the collimator in front of and behind the focal point. Technetium-99m point source sensitivities m...