1.2-MeV Atomic Resolution Holography Electron Microscope
نویسندگان
چکیده
منابع مشابه
Development of Holography Electron Microscope with Atomic Resolution
THE transmission electron microscope was invented in Germany in 1932. It works by directing a beam of electrons through a specimen and then using a lens to enlarge the image formed by their passage. In Japan, development and research into its applications began in 1939, and numerous companies around the world have competed to develop the instruments since Hitachi developed its own fi rst transm...
متن کاملResolution in Electron Microscope Radioautography
Experimental resolution values, half distances (HD), were determined for electron microscope radioautography with (14)C as the source of radioactivity. These were about a factor of 1.5-2 times higher than for tritium. Grain distributions normalized in units of HD were found to fit the "universal" curves previously obtained for tritium.
متن کاملFull-resolution inline electron holography (FRIH)
Introduction: The term ‘electron holography’ is typically synonymous with ‘off-axis electron holography’ performed by interfering different parts of a coherent electron wave function using an electrostatic biprism. In addition to being a much simpler experiment, it has been shown that inline holography can be just as quantitative [1], can achieve much better signal/noise properties for the same...
متن کاملPhase modulation atomic force microscope with true atomic resolution
We have developed a dynamic force microscope DFM working in a novel operation mode which is referred to as phase modulation atomic force microscopy PM-AFM . PM-AFM utilizes a fixed-frequency excitation signal to drive a cantilever, which ensures stable imaging even with occasional tip crash and adhesion to the surface. The tip-sample interaction force is detected as a change of the phase differ...
متن کاملElectron holography surmounts resolution limit of electron microscopy.
In high resolution electron{oo-axis holography, the complete information about amplitude and phase of the complex electron image wave is captured in a single hologram, fed to a computer, numerically reconstructed and analysed using methods of wave optical image processing. Speciically, the blurring eeect due to the aberration of the objective lens of the electron microscope is corrected under r...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Materia Japan
سال: 2019
ISSN: 1340-2625,1884-5843
DOI: 10.2320/materia.58.334