1131 Robust semi-automatic computer-aided segmentation of the left ventricle
نویسندگان
چکیده
منابع مشابه
1131 Robust semi - automatic computer - aided segmentation of the left ventricle
Introduction Left ventricular assessment with CMR calls for extensive delineation from increasingly large datasets, especially for serial examinations. In these cases, manual segmentation is tedious and also involves significant interand intraoperator variability. Computer-aided approaches that help automate the delineation are fallible to a range of problems that affect automatic image segment...
متن کاملAutomatic Segmentation of Left Ventricle in Ultrasound Images
The segmentation of left ventricle in ultrasound imaging of human heart would provide an important clinical parameter for the evaluation of cardiac functions including volume stroke or ejection fraction and wall motion tracking. We propose a real-time segmentation method to reduce laborious manual efforts and conveniently provide robust and stable cardiac quantification to users. The proposed m...
متن کاملA semi-automatic computer-aided method for surgical template design
This paper presents a generalized integrated framework of semi-automatic surgical template design. Several algorithms were implemented including the mesh segmentation, offset surface generation, collision detection, ruled surface generation, etc., and a special software named TemDesigner was developed. With a simple user interface, a customized template can be semi- automatically designed accor...
متن کاملAutomatic Localization of the Left Ventricle from Cardiac Cine Magnetic Resonance Imaging: A New Spectrum-Based Computer-Aided Tool
Traditionally, cardiac image analysis is done manually. Automatic image processing can help with the repetitive tasks, and also deal with huge amounts of data, a task which would be humanly tedious. This study aims to develop a spectrum-based computer-aided tool to locate the left ventricle using images obtained via cardiac magnetic resonance imaging. Discrete Fourier Transform was conducted pi...
متن کاملExtracting the Fine Structure of the Left Cardiac Ventricle in 4D CT Data - A Semi-Automatic Segmentation Pipeline
We propose a pipeline for the segmentation of the left cardiac ventricle (LV) in 4D CT data based on the random walker (RW) algorithm. A segmentation of the LV allows to extract clinical relevant parameters such as ejection fraction (EF) and volume over time (VoT), supporting diagnostic and therapy planning. The presented pipeline works aside approaches incorporating annotated databases, statis...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Cardiovascular Magnetic Resonance
سال: 2008
ISSN: 1532-429X
DOI: 10.1186/1532-429x-10-s1-a256