Cardiac Resynchronization Therapy; Biventricular Pacing
Although the estimates from limited studies vary on the proportion of patients with heart failure who also have ventricular dyssynchrony as reflected by a prolonged QRS complex, often in the form of left bundle branch block, the number of such patients is large (27% to 53%) and it is certainly in excess of the rate for the general population. Among these patients, 10% to 15% are candidates for ...
متن کاملAcute effects of biventricular pacing on right ventricular function assessed by tissue Doppler imaging.
AIMS The benefits of cardiac resynchronization therapy (CRT) on functional status, left ventricular (LV) remodelling and survival in patients with drug-refractory congestive heart failure (CHF), LV systolic dysfunction, and wide QRS have been demonstrated in randomized trials. However, the impact of CRT on right ventricular (RV) function, an independent prognostic factor in CHF remains question...
متن کاملBiventricular pacing-induced acute response in baroreflex sensitivity has predictive value for midterm response to cardiac resynchronization therapy.
In a previous study we demonstrated that the institution of biventricular pacing in chronic heart failure (CHF) acutely facilitates the arterial baroreflex. The arterial baroreflex has important prognostic value in CHF. We hypothesized that the acute response in baroreflex sensitivity (BRS) after the institution of cardiac resynchronization therapy (CRT) has predictive value for midterm respons...
متن کاملBiventricular mechanical asynchrony predicts hemodynamic effect of uni- and biventricular pacing.
We tested whether biventricular resynchronization explains contractile function changes with univentricular and biventricular pacing in heart failure patients with varying magnitudes of baseline biventricular asynchrony. Thirty patients (New York Hospital Association class > or = III, QRS duration > or =120 ms) were tested. Contractile function was measured by left ventricular maximum first der...
متن کاملHeart failure devices: implantable cardioverter-defibrillators and biventricular pacing therapy.
Although the age-adjusted mortality from heart disease has declined in the United States, cardiovascular disease remains the No. 1 cause of death.1,2 Patients with cardiac disease generally die of one of 2 causes: sudden, unexpected cardiac death or progressive heart failure. Chronic heart failure (CHF) has become an epidemic in the United States. Implantable cardioverter-defibrillator (ICD) th...