1055 Effect of Dimensions of Light-Weight Concrete Specimen on Compressive Strength (Materials and Execution)
نویسندگان
چکیده
منابع مشابه
the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)
cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...
Investigating the Effect of Specimen Diameter Size on Uniaxial Compressive Strength and Elastic Properties of Travertines
Uniaxial compressive strength (UCS) and elastic properties of rocks play a major and vital role for the design of any engineering structure. The specimen diameter size is one of the main factors that influencing on UCS, elasticity modulus and Poisson’s ratio (E and υ). Here, an attempt has been made to investigate the effect of specimen diameter size on UCS, E and υ. Moreover, we studied the co...
متن کاملthe effect of esp materials on medical studentsreading proficiency
چکیده این تحقیق " مواد درسی " را به عنوان یکی از بحث برانگیزترین موضوعات آموزش زبان تلقی کرده و درتلاش است به سه سوال عمده پاسخ دهد: 1) آیا بکارگیری جزوات گرداوری شده توسط گروهی از مدرسین تاثیر بسزایی در میزان توانش خواندن و درک متون انگلیسی دانشجویان پزشکی دارد؟ 2) آیا استفاده از مواد درسی اصلی( بین المللی )، توانش خواندن و درک متون انگلیسی دانشجویان پزشکی را به طور چشمگیری تحت تاثیر قرار م...
15 صفحه اولthe effect of explicit teaching of metacognitive vocabulary learning strategies on recall and retention of idioms
چکیده ندارد.
15 صفحه اولCompressive strength of glass ionomer cements using different specimen dimensions.
The purpose of this study was to evaluate the compressive strength of two glass ionomer cements, a conventional one (Vitro Fil - DFL) and a resin-modified material (Vitro Fil LC - DFL), using two test specimen dimensions: One with 6 mm in height and 4 mm in diameter and the other with 12 mm in height and 6 mm in diameter, according to the ISO 7489:1986 specification and the ANSI/ADA Specificati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan Summaries of Technical Papers
سال: 1967
ISSN: 2433-0035
DOI: 10.3130/aijsaxxe.42.0_55