1033) Volume Change of Concretes at Various Humidity : Preliminary Tests(Materials, Execution)
نویسندگان
چکیده
منابع مشابه
Evaluation of sustainable high-volume fly ash concretes
This article presents experimental research work oriented toward developing practical design tools for industrial application, and illustrates the potential benefits of the synergistic effect of an ASTM C 618 Class F fly ash (FA) and a high-range polycarboxylate superplasticizer (SP) in the production of conventional concrete. The different concretes considered in this study were produced with ...
متن کاملThermal Properties of High-Volume Fly Ash Mortars and Concretes
As sustainability moves to the forefront of construction, the utilization of high volume fly ash concrete mixtures to reduce CO2 emissions and cement consumption per unit volume of concrete placed is receiving renewed interest. Concrete mixtures in which the fly ash replaces 50 % or more of the portland cement are both economically and technically viable. This paper focuses on a characterizatio...
متن کاملMixture Proportioning Options for Improving High Volume Fly Ash Concretes
High volume fly ash (HVFA) concretes are one component of creating a more sustainable infrastructure. By replacing 50 % or more of the Portland cement with fly ash, a significant reduction is achieved in the carbon footprint of the in place concrete. While HVFA mixtures can be proportioned to produce equivalent long term performance as conventional (cement-only) mixtures, performance problems a...
متن کاملChange of proton gradient in mitochondria at various energy states.
Changes of H+ gradient at various energy states of mitochondria were studied. There was a close relation between the extent of H+ gradient and the level of ATP formation; the former decreased as a result of ATP synthesis but was not completely abolished. A partial depression of H+ gradient was also observed in the presence of uncouplers of oxidative phosphorylation. The H+ gradient seemed to be...
متن کاملChange of footwear insulation at various sweating rates.
Moisture inside the footwear can considerably affect the thermal insulation. In this study with a thermal foot model there was simulated three sweat rates (3, 5 and 10 g/h). Five types of footwear with various insulation levels (dry insulation from 0.19 to 0.50 m2. K/W) were tested. The footwear insulation reduction was calculated for 1.5 hour period. The reduction in insulation was related to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Architectural Institute of Japan
سال: 1962
ISSN: 0387-1185,2433-0027
DOI: 10.3130/aijsaxx.76.0_33