1025: Adherence to ≤ 8 Milliliters Tidal Volume per Ideal Body Weight in Mechanically Ventilated Patients
نویسندگان
چکیده
منابع مشابه
Humidification and secretion volume in mechanically ventilated patients.
OBJECTIVE To determine potential effects of humidification on the volume of airway secretions in mechanically ventilated patients. METHODS Water vapor delivery from devices providing non-heated-wire humidification, heated-wire humidification, and heat and moisture exchanger (HME) were quantified on the bench. Then, patients requiring 24-hour mechanical ventilation were exposed sequentially to...
متن کاملEffect of tidal volume and frequency on airway responsiveness in mechanically ventilated rabbits.
We evaluated the effects of the rate and volume of tidal ventilation on airway resistance (Raw) during intravenous methacholine (MCh) challenge in mechanically ventilated rabbits. Five rabbits were challenged at tidal volumes of 5, 10, and 20 ml/kg at a frequency of 15 breaths/min and also under static conditions (0 ml/kg tidal volume). Four rabbits were subjected to MCh challenge at frequencie...
متن کاملBronchoscopy in Mechanically Ventilated Patients
The origins of bronchoscopy date back to 1897 when Gustav Killian, considered “the father of bronchoscopy”, performed the first airway examination with a rigid esophagoscope to a farmer extracting a piece of bone that had lodged in the main stem bronchus. Shigeto Ikeda in 1964 revolutionized the field of bronchoscopy with the introduction of a flexible instrument that could be introduced to sub...
متن کاملIs the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
A transversal and interventional study that included 30 critically ill patients with acute circulatory failure, sedated and mechanically ventilated with a tidal volume of 6 to 7 ml/kg. Mechanical ventilatory measurements including positive end-expiratory pressure plateau and peak pressures, static compliance and hemodynamic measurements including PPV, heart rate, mean systemic and pulmonary art...
متن کاملcorrelation of end-tidal carbon dioxide with arterial carbon dioxide in mechanically ventilated patients
background: patients undergone mechanical ventilation need rapid and reliable evaluation of their respiratory status. monitoring of end-tidal carbon dioxide (etco2) as a surrogate, noninvasive measurement of arterial carbon dioxide (paco2) is one of the methods used for this purpose in intubated patients. objectives: the aim of the present trial was to study the relationship between end-tidal c...