1000-volume/s high-speed volumetric display for high-speed HMD
نویسندگان
چکیده
منابع مشابه
High-Speed Penternary Inverter Gate Using GNRFET
This paper introduces a new design of penternary inverter gate based on graphene nanoribbon field effect transistor (GNRFET). The penternary logic is one of Multiple-valued logic (MVL) circuits which are the best substitute for binary logic because of its low power-delay product (PDP) resulting from reduced complexity of interconnects and chip area. GNRFET is preferred over Si-MOSFET for circui...
متن کاملHigh Speed Delay-Locked Loop for Multiple Clock Phase Generation
In this paper, a high speed delay-locked loop (DLL) architecture ispresented which can be employed in high frequency applications. In order to design the new architecture, a new mixed structure is presented for phase detector (PD) and charge pump (CP) which canbe triggered by double edges of the input signals. In addition, the blind zone is removed due to the elimination of reset signal. Theref...
متن کاملPhase Frequency Detector Using Transmission Gates for High Speed Applications
In this paper a new phase-frequency detector is proposed using transmission gates which can detect phase difference less than 500ps. In other word, the proposed Phase-frequency Detector (PFD) can work in frequencies higher than 1.7 GHz, whereas a conventional PFD operates at frequencies less than 1.1 GHz. This new architecture is designed in TSMC 0.13um CMOS Technology. Also, the proposed PFD a...
متن کاملComputed optical interferometric tomography for high-speed volumetric cellular imaging.
Three-dimensional high-resolution imaging methods are important for cellular-level research. Optical coherence microscopy (OCM) is a low-coherence-based interferometry technology for cellular imaging with both high axial and lateral resolution. Using a high-numerical-aperture objective, OCM normally has a shallow depth of field and requires scanning the focus through the entire region of intere...
متن کاملHigh-speed switchable lens enables the development of a volumetric stereoscopic display.
Stereoscopic displays present different images to the two eyes and thereby create a compelling three-dimensional (3D) sensation. They are being developed for numerous applications including cinema, television, virtual prototyping, and medical imaging. However, stereoscopic displays cause perceptual distortions, performance decrements, and visual fatigue. These problems occur because some of the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2020
ISSN: 1094-4087
DOI: 10.1364/oe.401778