024 Validation with thallium 201 of a new cadmium-zinc-telluride (CZT) cardiac camera

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low-dose thallium-201 protocol with a cadmium-zinc-telluride cardiac camera.

OBJECTIVES Thallium-201 is efficient for myocardial perfusion imaging, but leads to relatively high radiation exposure in patients. The purpose of this study was to compare the efficiency of low-dose thallium-201 imaging with cadmium-zinc-telluride (CZT) cameras with regular-dose thallium-201 imaging with conventional cameras. METHODS We prospectively studied 137 consecutive patients referred...

متن کامل

Electric Field Distribution of Cadmium Zinc Telluride (CZT) Detectors

Cadmium Zinc Telluride (CZT) is attracting increasing interest with its promise as a room-temperature nuclear-radiationdetector material. The distribution of the electric field in CZT detectors substantially affects their detection performance. At Brookhaven National Laboratory (BNL), we employed a synchrotron X-Ray mapping technique and a Pockels-effect measurement system to investigate this d...

متن کامل

The Cadmium Zinc Telluride (CZT) Detector Array Innovation Pathway

This pathway describes the development of soft gamma-ray/hard x-ray detector arrays at NASA’s Goddard Space Flight Center (GSFC, or Goddard), through a collaboration between the gamma-ray spectroscopy group and the detector branch. The Cadmium Zinc Telluride (CdZnTe, or CZT) detectors which resulted from this decade-long development were first flown on the wildly successful SWIFT mission in 200...

متن کامل

Cardiac Scintigraphy with Thallium-201 and Technetium Pyrophosphate

myocardial Scintigraphy ischemia can deor mc_mstrat_e mfarction. and It  has a higrs after onset of an mfarctl has a higrs after onset of an mfarctln and localizeh sensitivity in the first six to.twenty can belabelled pyrophosphate scan becomes four.  houuseful in the coronary care umt. The positive trction. Since the pyrophosphate scan 99mTc welve to twenty hours after onset of an becomes infa...

متن کامل

Evaluation of left ventricular diastolic function with a dedicated cadmium-zinc-telluride cardiac camera: comparison with Doppler echocardiography.

AIMS To evaluate the relationships between measures of left ventricular (LV) filling dynamics at cadmium-zinc-telluride (CZT) imaging and indexes of LV diastolic function at transthoracic echocardiography. METHODS AND RESULTS Two hundred and forty-seven patients underwent myocardial perfusion imaging at rest and after stress with a low-dose CZT protocol and a baseline transthoracic echocardio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Archives of Cardiovascular Diseases Supplements

سال: 2011

ISSN: 1878-6480

DOI: 10.1016/s1878-6480(11)70026-x